Hmi touch screen panel manufacturer and supplier right now: Choosing the right industrial hmi touch screen panel and plc can not only adapt to the electrical room’s multi-interference operation environment, but also enable each cabinet to achieve intelligent operation management, intelligent maintenance safety, intelligent new energy generation, etc., in order to achieve the goal of enhancing the electrical room’s core competitive advantage and promoting the sustainable development of electricity. See additional information on hmi touch screen.
Specifically, the two-way communication between the HCI user and the machine containing the computer, in a certain symbol and actions to achieve, such as hitting keys, moving the mouse, displaying symbols/graphics on the screen, etc. This process includes several sub-processes: identifying the interactive object – understanding the interactive object – grasping the object situation – information adaptation and feedback, etc.; and the human-machine interface is the communication media or means between the user and the machine system containing the computer, which is the software and hardware supporting the two-way information interaction between human and machine. Here the interface is defined as the media or means of communication, and its physical embodiment is the relevant supporting software and hardware, such as a graphic display terminal with a mouse, etc.
Response Speed Requirements: PLC is a general controller designed for industrial automation, and the response speed of different grades of PLC can generally meet the needs of its application range. If you wanna use plc across the range, or some functions or signals have special speed requirements, you should carefully consider the response speed of the plc, you can choose a plc with high-speed i/o processing function, or choose a plc with a fast response module and an interrupt input module.
Order principle: That is, in accordance with the order of processing events, access to view the order (such as from the whole to a single item, from large to small, from the top to the bottom, etc.) and control processes, such as the design of monitoring management and human-machine dialogue interface and its secondary interface. Functional principle: That is, according to the specific functional requirements of the object application environment and occasions, various subsystem control types, parallel processing requirements of the same interface of different management objects and simultaneous requirements of multiple dialogues, etc., the human-computer interaction interface is designed with multi-level menus, hierarchical prompt messages and multiple dialogues, so that users can easily distinguish and master the usage rules and characteristics of the interactive interface and improve its user friendliness and ease of operation.
Determine the task that should be performed by human and computer respectively to complete the system function: There are two ways of task analysis. One is to start from the actual, through the analysis of the original application system in a manual or semi-manual state, it will be mapped to a set of similar tasks performed on the human-computer interface; the other is to study the system requirements specifications to derive a set of user tasks coordinated with the user model and system assumptions. Techniques such as stepwise refinement and object-oriented analysis are also applicable to task analysis. Stepwise refinement techniques can continuously divide the task into subtasks until the requirements for each task are clear; and object-oriented analysis techniques can be used to identify all the objective objects associated with the application and the actions associated with the objects.
The reason is rs232 is suitable for communication between local devices, and its transmission distance is generally not more than 15m, and rs232 only allows one-ton-one communication. But rs485 transmission distance is from tens of meters up to 2Km, and rs485 interface allows up to 255 slave station to be connected. These are required to be designed by our engineers, with whom to communicate, how many devices to communicate, how to achieve the final function, whether to take into consider the interference problems of the field environment etc. All of the above are considered.
Supporting customized special technical parameters, special application scenarios or special process, special function realization, special performance, special application including shape, color etc. With NO MOQ before mass production. And will not accept to quantity production before customer 100% confirmation its stable quality to run in the device or equipment. Becuase quality is the soul of an enterprise. MochuanDrives customized pmsm motor mainly focuses on high-tech , high-end development, design, production, sales. See even more details on mochuan-drives.com.
Why touch panel interface always fail to communicate with PLC? Common reasons why touchscreens do not communicate with PLCs 1. whether the correct communication protocol is selected (Modbus, Profibus, CANopen, etherCAT) 2. Is the communication line normal (RS232 rxd TXD GND RS485 a+B-CANopen CAN_L CAN_H CAN_GND ether cat network cable) 3. Whether the communication parameters are correct (station number, baud rate, parity bits) 4. Whether there is interference The program determines that the communication between HMI operator interface and plc has fialed
This type touchscreen panel support 7inch, 9.7inch, 17inch, 22inch and 32inch, is enough to select suitable model for the project from application and cost. There are two operating temperature -10°C to 60°C and -20°C to 70°C. And all the size and model is to support ethernet, 2pcs rs485 or 2pcs rs232 is in optional. Adpoting industrial grade high quality components, high protection level design, comprehensive three-proof coating, no matter the wet underground mine, high temperature gobi or corrosive gas, oil mist or dust factory environment, can easily cope with, easy to handle.
There are lots of temperature control in industry automation. It can select temperature module match the main module plc temperature controller, it also use independent temperature controller to control, both of them are to achieve temperature control. If wanna more flexibility in temperature control, maybe indenpendent temperature module is the first choice. Becuase it can operate without main module plc controller. Mochuan independent plc temperature module integrates an excellent self-tuning algorithm, and user can auto-tune with one button according to needs to accurately obtain PID parameters. Through rs485 communication port, communicate with upper computers of various brands, types of plc, touch screen hmi, configuration software and other upper computers to complete morecomplex logic temperature control.